Browse all practice questions for the Commercial Food Equipment Service Association (CFESA) Refrigeration Certification Practice Test. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

CFESA Refrigeration Certification Practice Test 2026 – Complete Prep Guide course image
More practice questions

These questions are part of the practice quiz. Start practicing

  • Which of the following is a key component in assessing the health of a refrigeration system?
  • What does the coefficient of performance (COP) indicate?
  • Which of the following is NOT a main component of a refrigeration system?
  • Why is a proper refrigerant charge critical in refrigeration systems?
  • Which of the following best describes the process of condensation in a refrigeration system?
  • A dark colored moisture indicator sensor suggests what condition in a refrigeration system?
  • Which part of the refrigeration system is crucial for removing moisture?
  • What line is typically used to provide heat for evaporating condensate in many commercial reach-in boxes?
  • How is a coil on a current relay typically connected?
  • What environmental factor can contribute to compressor failures?
  • Which statement is true regarding R134A?
  • What is a possible cause for the suction valves snapping off when the compressor head is removed?
  • What should you do if an ohmmeter reads infinity ohms when checking a start capacitor?
  • What can cause frost build-up around the evaporator coil?
  • What should be done if there are bubbles in the sight glass of a refrigeration system?
  • What is the primary benefit of balanced port expansion valves?
  • What happens at the expansion valve in a refrigeration system?
  • What action is needed to ensure the suction pressure remains the same during testing?
  • Where should a temperature sensor be installed to accurately calculate subcooling?
  • How does a balanced port expansion valve differ from other types?
  • What is the function of a defrost termination thermostat on a walk-in freezer?
  • Where should the sensor bulb on an external equalized TXV be mounted?
  • What is the primary function of a fan delay thermostat in commercial freezers?
  • In subcooling calculations, why is the position of the temperature sensor important?
  • What is the typical duration set for defrost timers in commercial freezers?
  • When evacuating a refrigeration system, which tool is essential to ensure a proper evacuation?
  • Which component helps prevent corrosion in a refrigeration system?
  • Why is monitoring ambient temperature crucial in refrigeration systems?
  • Which factor is crucial when selecting a pump for evacuating refrigeration systems?
  • What is a common method to identify leaks in a refrigeration system?
  • What is important to consider when re-soldering refrigerant lines?
  • What does the term 'latent heat' refer to in refrigeration contexts?
  • What is the purpose of an evaporator fan in commercial refrigeration?
  • What role do defrost timers play in commercial refrigeration systems?
  • What is the purpose of a condenser in the refrigeration cycle?
  • What does the compression ratio represent in refrigeration systems?
  • Where must the sensor bulb on a TEV be installed on the suction line?
  • What safety precautions should be observed while working with refrigeration systems?
  • What instrument is used to measure the pressure in a refrigeration system?
  • When checking for correct superheat on a cap tube system, what condition is required?
  • How are cooler evaporators typically defrosted?
  • What preventative measures can help avoid compressor failure?
  • Why can pressure controls not be used as the sole source of temperature control in outdoor temperature climates?
  • When bubbles are present in a sight glass, what does this indicate when using near azeotropic refrigerants?
  • Where is a run capacitor connected in a motor system?
  • What is the benefit of using leak detectors in refrigeration maintenance?
  • How do you reduce the superheat on a thermal expansion valve?
  • What environmental factor significantly impacts the efficiency of condensing units in refrigeration systems?
  • What is a potential consequence of neglecting regular maintenance on refrigeration equipment?
  • Excessive moisture in a reach-in cooler typically suggests what issue?
  • What is a major consequence of undercharging a refrigeration system?
  • For maximum system efficiency, the TEV superheat for a cooler should be about:
  • What could happen if the condenser fan motor is not cleaned?
  • Why are forced air evaporator coils commonly used in refrigeration systems?
  • What type of contacts are found on a current relay?
  • When replacing valve plates or service valves, what should be used to lubricate the gaskets?
  • Which refrigerant would you convert a walk-in freezer to when replacing the condensing unit on an R502 system?
  • What determines the size of the metering device needed for a refrigeration system?
  • Which factor is essential for maintaining optimal performance in a refrigeration system?
  • When a compressor kicks the circuit breaker while starting, what could be the likely problem if the FLA rating is 7 amps?
  • What is a common characteristic of a high-quality vacuum pump used in system evacuation?
  • What condition can cause discharge valves and backing plates on a compressor valve plate to be deformed?
  • What is the importance of proper insulation in refrigeration systems?
  • Which condition likely indicates a problem when turning off a refrigeration unit?
  • What action should be taken if the condenser is badly clogged?
  • Why is superheat crucial in a refrigeration system?
  • How can you confirm that a refrigeration system is properly charged?
  • What is the purpose of the suction line in a refrigeration system?
  • When replacing a refrigerant cap tube with a generic cap tube kit, what is the first step to follow?
  • What symptom might indicate a faulty thermostat in a refrigeration unit?
  • What is the total capacitance of two 100 uf capacitors connected in parallel?
  • What is a characteristic of a near azeotrop refrigerant?
  • How does a compressor function within a refrigeration system?
  • What is the primary risk of using a run capacitor that is not functioning properly?
  • What can help mitigate the issue of bubbles showing in sight glasses with a full charge?
  • Which process occurs in the evaporator coil?
  • What usually causes partial or complete clogging in capillary tubes?
  • What effect does a missing condenser fan shroud have on discharge pressure?
  • What does the start relay disconnect when the motor reaches about 2/3 of its full speed?
  • What happens to a refrigeration system when moisture is present?
  • What is the main role of an accumulator in a refrigeration system?
  • What is the purpose of a water regulating valve in a water-cooled condenser?
  • If a compressor has a rated FLA of 20A but is drawing 26A while running, what is a possible issue?
  • What is subcooling in the context of refrigeration systems?
  • For maximum efficiency, the thermal expansion valve superheat for a freezer should be about:
  • What should be done if an evaporator has an external equalized TEV, but only an internal equalized valve is available?
  • Where is the best location to remove acid from a refrigerant system?
  • What is a typical symptom of a malfunctioning compressor?
  • A missing condenser fan shroud on a cap tube system will probably lead to what?
  • How does ambient temperature impact refrigeration system performance?
  • Why is it necessary to remove a grease-covered condenser?
  • What is the primary reason a condensing unit located in a restricted space will run higher than normal head pressures?
  • In order to maintain proper temperature under various loads, a cooler or freezer located on a front prep line must be equipped with:
  • After servicing a cap tube system and replacing the drier with a larger one, what is the best way to recharge it?
  • What type of oil is recommended for use with refrigerant R404A?
  • What is the consequence of dirty and clogged evaporator coils?
  • What happens when the defrost termination thermostat reaches its temperature limit?
  • Which component removes heat from the refrigerant, allowing it to cool and condense?
  • What is the maximum head pressure for an R404A system operating in an ambient temperature of 85°F?
  • Why might bubbles appear in sight glasses when using newer near azeotropic refrigerants?
  • What is a key aspect of maintaining balanced port expansion valves?
  • What is the primary purpose of a thermal expansion valve in a refrigeration system?
  • Which component is responsible for maintaining the refrigerant flow in the system?
  • What is the role of an electrical schematic in refrigeration troubleshooting?
  • What is a significant advantage of a balanced port TEV?
  • What is the best example of the definition of a storage box?
  • If the liquid line out of the liquid line drier is frosted, what does this suggest?
  • What occurs to the water flow rate when the condensing unit is off?
  • Why must a condenser fan blade be replaced with the exact factory-supplied blade?
  • In low temperature climates, what is the most efficient method for temperature control?
  • What is the recommended oil level in the sight glass of a running semi-hermetic compressor?
  • When replacing driers for newer refrigerants, what size should they be?
  • What is superheat in the context of refrigeration?
  • What is the primary purpose of a refrigeration system in commercial food service?
  • If the oil sight glass in a compressor shows almost no oil and there are no leaks, what should be the next step?
  • What type of maintenance is necessary for condensers in refrigeration systems?
  • What pressure corresponds to 20°F on R404A?
  • What is a thermal expansion valve (TXV) used for in refrigeration systems?
  • How should R404A be charged into a refrigeration system?
  • What could lead to a malfunctioning thermal expansion valve?
  • Which phrase best describes the proper use for a refrigerated box using a cap tube system?
  • What should be monitored to prevent damage to relay contacts in a compressor's circuitry?
  • Where is a pump down solenoid valve typically located?
  • Why is regular maintenance important for refrigeration systems?
  • If the TD of an evaporator coil should be 15 ° and you measure only 5 °, what could be the issue if other pressures check out?
  • What is the main function of a drier in a refrigeration system?
  • Why is a bleed resistor necessary on a start capacitor?
  • Where must the sensor bulb on a TEV be mounted?
  • What is true about compression ratio in relation to volumetric efficiency?
  • If a cap tube is partially clogged, what is an expected condition?
  • What does the milky color of oil in a compressor most likely indicate?
  • Which refrigerants are commonly used in commercial refrigeration systems?
  • What is the most common cause of leaks in the middle of a copper line?
  • If a start capacitor rated at 240 uf and 225 volts is faulty, which capacitor can be used instead?
  • What is the procedure for checking the suction valves on a compressor?
  • What is an essential part of routine maintenance for refrigeration systems?
  • When converting a system from R502 to R404A, what can you do with the TEV?
  • What is an interim refrigerant choice for an R502 system with a major leak?
  • Where should a trap be installed when piping refrigerant lines in a system with the compressor above the evaporator?
  • How should one check the discharge valves on a compressor?
  • What factor can lead to compressor overheating in a refrigeration system?
  • What is a common cause for evaporator failures in reach-in coolers?
  • What must be matched when replacing an evaporator fan motor?
  • Why is measuring compression ratio critical for a compressor's life?
  • A system that runs at a superheat of 1 ° F will likely result in what?
  • What is the status of contacts on a potential relay when not energized?
  • How many BTUs per hour is one ton of refrigeration equal to?
  • Which cleaning agents are advisable for servicing refrigeration coils?
  • Where should the discharge temperature be measured in a refrigeration system?
  • What does the capacity of a one horsepower compressor depend on?
  • What should be checked when a compressor is operating inefficiently?
  • Which box operates with higher humidity based on the temperature difference?
  • What does it indicate if a compressor is short-cycling?
  • Which maintenance task is critical for evaporators?
  • What impact do high superheat settings have on a refrigeration system?
  • What happens to the compressor when the condensing temperature at the compressor head reaches 350 °?
  • What is the main purpose of the expansion valve in refrigeration?
  • Why is it crucial to adhere to EPA regulations in refrigeration service?
  • What leads to effective acid removal from the refrigerant?
  • Which tool is essential for troubleshooting refrigeration issues?
  • Where must a static condenser be installed?
  • What is the best course of action when there are concerns with refrigerant levels in a compressor with low oil?
  • Which of the following is a sign of a refrigerant leak?
  • What is the purpose of a low-pressure switch in refrigeration systems?
  • What is a common reason for a refrigeration system to fail to activate cooling?
  • When should a suction drier be left in the refrigeration line?
  • What is a sign of a compressor burnout?
  • What is the most important line to ensure proper oil return during piping installation?
  • Why is refrigerant classification important for refrigeration systems?
  • What commonly contributes to high head pressure in a refrigeration unit?
  • What are signs indicating a malfunctioning expansion valve?
  • When evacuating a refrigeration system, to what micron level should it ideally be evacuated?
  • Why is it important to clean grease buildup on the condenser fan motor and blade?
  • In a low-temperature refrigeration system, the majority of Btu of cooling is required to remove what?
  • What is a common reason for the premature failure of replacement compressors?
  • What could be a potential risk if the compressor fails in a refrigeration system?
  • What causes excess superheat increase on the way to the compressor?
  • What does icing around a freezer door frame typically indicate?
  • What does a dark brown or black color with carbon deposits on a compressor's valve plate indicate?
  • What is the role of the condenser in the refrigeration cycle?
  • What is a crucial reason for insulating the suction line?
  • What effect does temperature have on the performance of refrigeration systems during evacuation?
  • If the shroud is missing from the condenser on a condensing unit, what should be done?
  • A cap tube is ineffective on most commercial refrigeration systems because:
  • What issue is indicated by the oil sight glass showing almost no oil in a compressor?
  • Why do modern three-phase compressors often require crankcase pressure regulating (CPR) systems?
  • What type of oil is most commonly used with CFC refrigerants?
  • How can you identify a compressor that suffered from liquid slugging?
  • How does a two-stage refrigeration system operate?
  • What is the maximum allowable discharge temperature to prevent probable compressor failure?
  • An R404A cooler system with a cap tube has a head pressure of 336 psi. What may this indicate?
  • Where is the most effective place to remove moisture from refrigerant?
  • When should a cap tube be considered for use in a refrigeration system?
  • What is an effect of not addressing low refrigerant levels?
  • During a system operation using R134A, what does the system indicate if the suction pressure falls to 15 psi and then into a vacuum?
  • What is the appropriate method to perform a leak check in a refrigeration system?
  • The new interim refrigerants R401A, R401B, and R409A have what characteristic related to heat carrying capacity?
  • In a potential relay, how is the coil typically wired?
  • What is a potential consequence of improper refrigerant levels in a refrigeration system?
  • According to HACCP food safety regulations, what temperature must coolers maintain?
  • An automatic expansion valve does not:
  • Is it advisable to install a sight glass in a cap tube system?
  • Which refrigerant is a suitable interim replacement for R-12?
  • What happens if the condenser fan fails in a refrigeration system?
  • In a system with R134A operating at 146 psi head pressure and 100°F condenser temperature, what is the subcooling measured?
  • What is the maximum allowable voltage difference for a balanced three-phase compressor?
  • What is the maximum temperature a freezer must maintain to ensure proper operation?
  • What maintenance action is necessary for a refrigeration compressor after a defrost cycle?
  • What are common refrigerant types used in commercial kitchens?
  • What is a key disadvantage of using an automatic expansion valve?
  • What is the main consequence of improper refrigerant charge?
  • Where should a sight glass/moisture indicator be installed in a refrigeration system?
  • In what way does the refrigeration cycle specifically differ from the air conditioning cycle?
  • A water-cooled condenser that is operating properly will have what characteristic regarding discharge water temperature?
  • What is indicated by the terminal marked as 'A' in a common terminal identification?
  • Which condition can lead to compressor failure due to high temperatures?
  • When is it necessary to replace a compressor?
  • What is the primary function of an accumulator in a refrigeration system?
  • What is a common issue with coolers and freezers that use a coiled discharge line in a pan for condensate removal?
  • What does a dry system indicated by a moisture indicator imply for the refrigeration system's functionality?
  • What is one way to maintain proper airflow in a refrigeration system?
  • How does regular maintenance benefit refrigeration systems?
  • What is the primary purpose of a run capacitor in a compressor system?
  • Which refrigerant serves as a drop-in replacement for R502?
  • When should a condenser capacity be assessed?
  • If an R404A system has a suction pressure of 29 psi and a head pressure of 239 psi, what is the superheat?
  • What is the role of the evaporator in a refrigeration system?
  • What is the main purpose of using a properly designed drier in a refrigeration system?
  • When sizing the piping for a refrigeration system, which line is most critical?
  • What causes a refrigeration system to run continuously?
  • What is typically the first sign of a cap tube issue?
  • After completing repairs on a freezer, why might the temperature stop dropping at 35 degrees?
  • What could indicate that a refrigeration system is overcharged?
  • What effect does insufficient refrigerant charge have on a refrigeration system?
  • If the suction line to a compressor using a TEV is frosted and iced up, it could indicate what issue?
  • Which type of cleaner is most effective for cleaning greasy condenser coils?
  • What characteristic of mineral oil makes it suitable for use with CFC refrigerants?
  • What equipment should be installed to handle the system for newer refrigerants?
  • What is the primary function of the compressor in a refrigeration system?
  • In refrigeration systems, what role does a sight glass play when properly installed?
  • What should be done to a grease-laden air-cooled condenser?
  • What is a common indicator of a clogged filter in a refrigeration system?
  • What function does the evaporator serve in a refrigeration system?
  • What does proper refrigerant handling ensure?
  • What is the primary function of the high-pressure switch in a refrigeration system?
  • What is a major problem with POE oil?
  • When is it necessary to evacuate a refrigeration system?
  • How should a fan blade be positioned in an evaporator or condenser?
Subscribe

Get the latest from Examzify

You can unsubscribe at any time. Read our privacy policy